AC Generator EMF Calculator – Peak & RMS EMF ε = NBAω

Use this free AC Generator EMF Calculator to find the peak and RMS voltage produced by a coil rotating in a magnetic field, using ε = NBAω, from the turns, field strength, coil area and rotation speed.

N S rotates at ω coil of N turns, area A, in field B

Formula

εpeak = N × B × A × ω, where ω = 2π × (rpm ÷ 60) is the angular speed in rad/s. The output is a sine wave, ε = εpeak sin(ωt), so the RMS (effective) voltage is εrms = εpeak ÷ √2. More turns, a stronger field, a bigger coil or faster spinning all raise the voltage in direct proportion.

How to use

Worked example

A generator coil has N = 100 turns, area A = 0.02 m², in a field B = 0.4 T, spinning at 3000 rpm.
ω = 2π × 3000 ÷ 60 = 314.16 rad/s.
εpeak = NBAω = 100 × 0.4 × 0.02 × 314.16 = 251.33 V.
εrms = 251.33 ÷ √2 = 177.72 V.
That is the same order as mains electricity — power stations simply scale up every factor: thousands of turns, fields of ~1 T and huge coils.

FAQ

Why is the output AC and not DC?
As the coil turns, the flux through it rises, falls and reverses every half-turn, so the induced EMF follows a sine wave and swaps direction twice per revolution. A dynamo adds a split-ring commutator to flip the connections each half-turn and produce DC instead.

Why does the RMS value matter?
Because the voltage is constantly changing, we quote the RMS value — the steady DC voltage that would deliver the same average power. When a supply is labelled "230 V AC", that is its RMS value; its peaks actually reach about 325 V.

What limits a real generator's output?
The strength of the magnets or field coils, how fast the coil can safely spin, heating in the windings, and the mechanical power available to turn it. The EMF formula gives the ideal open-circuit voltage; drawing heavy current drops it slightly.