Internal Resistance Calculator – EMF & r from Two Load Measurements

Use this free Internal Resistance Two-Load Calculator to find a battery's EMF and internal resistance from two simple measurements: the terminal voltage at two different load currents. This is the standard school-lab method — no need to short-circuit anything.

V I (I1, V1) (I2, V2) E (intercept) slope = −r

Formula

Terminal voltage: V = E − Ir. From two measurements: r = (V1 − V2) / (I2 − I1)  •  E = V1 + I1 × r

How to use

Worked example

A battery shows V1 = 11.6 V while supplying I1 = 0.5 A, and V2 = 10.8 V while supplying I2 = 2 A.
r = (11.6 − 10.8) / (2 − 0.5) = 0.8 / 1.5 = 0.53 Ω.
E = 11.6 + 0.5 × 0.53 = 11.87 V.
Check with the second reading: 10.8 + 2 × 0.53 = 11.87 V — the same EMF, as it should be.

FAQ

Why use two loads instead of one measurement?
A single V and I pair mixes up the EMF and the internal resistance — infinitely many (E, r) pairs fit one point. Two points fix the straight line V = E − Ir, giving a unique slope (−r) and intercept (E).

Why not just measure the short-circuit current?
Shorting a battery can draw a huge current, overheating or damaging it (and the meter). The two-load method gets the same answer safely with ordinary loads.

Does internal resistance stay constant?
Not exactly — it rises as a battery ages, discharges or gets cold, which is why an old battery can show a healthy open-circuit voltage yet fail under load. Two-load measurements taken close together give a good snapshot value.