Use this free Manning Flow Calculator to find the flow speed and discharge in an open channel such as a ditch, canal or stream. Enter the channel width and water depth, Manning's roughness n and the slope — the calculator works out the hydraulic radius and applies Manning's equation.
Formula
Manning's equation: v = (1/n) × R^(2/3) × S^(1/2), then Q = A × v
For a rectangular channel of width b and depth y: the flow area is A = b × y, the wetted perimeter is P = b + 2y, and the hydraulic radius is R = A ÷ P. The slope S is the fall per unit length (0.001 means the bed drops 1 m every 1000 m).
How to use
- Enter Manning's n for the channel surface: smooth concrete 0.013, straight earth channel ≈ 0.025, natural stream with stones and weeds 0.035–0.05.
- Enter the width and the water depth in metres.
- Enter the slope as a decimal (a 1-in-1000 fall is 0.001) and click "Calculate Flow" to get the area, hydraulic radius, speed and discharge.
Worked example
A concrete channel (n = 0.013) is b = 2 m wide with water y = 1 m deep on a slope S = 0.001. A = 2 × 1 = 2 m², P = 2 + 2 = 4 m, so R = 0.5 m. Then v = (1 ÷ 0.013) × 0.5^(2/3) × √0.001 = 76.92 × 0.63 × 0.0316 = 1.53 m/s, and Q = 2 × 1.53 = 3.06 m³/s.
FAQ
What is the hydraulic radius?
It is the flow area divided by the wetted perimeter — the part of the channel boundary actually touching the water. A wide, shallow channel and a narrow, deep one can have the same area but very different hydraulic radii, and the deeper one flows faster because less of its water is slowed by the boundary.
What n value should I use?
n grows with roughness: 0.011–0.015 for finished concrete, 0.02–0.03 for earth channels, 0.035–0.05 for natural streams, and 0.1 or more for very rough, overgrown flood plains. When in doubt, tables in hydraulics references list n for many surfaces.
Does Manning's equation work for pipes?
Yes, for pipes flowing full or part-full the same equation applies with R = D/4 for a full circular pipe — but for pressurised pipe flow, head-loss formulas such as Darcy–Weisbach are usually preferred.