Pump Power Calculator – P = ρgQh with Efficiency
Use this free Pump Power Calculator to find the power needed to lift a liquid to a given height. Enter the density, flow rate and lift height (head), and optionally the pump efficiency to find the electrical input power the motor must supply.
Formula
Hydraulic power = ρ × g × Q × h → P = ρgQh (with g = 9.81 m/s²), and Input power = Hydraulic power ÷ efficiency
The hydraulic power is the useful power delivered to the liquid. A real pump wastes some energy as heat and friction, so the motor must supply more than this — dividing by the efficiency gives the true input power.
How to use
- Enter the liquid density in kg/m³ (water = 1000, seawater ≈ 1025).
- Enter the flow rate in m³/s — divide litres per second by 1000 (e.g. 20 L/s = 0.02 m³/s).
- Enter the vertical lift height in metres, and the efficiency in % if you know it, then click "Calculate Pump Power".
Worked example
A pump lifts water (ρ = 1000 kg/m³) at 0.02 m³/s through a height of 10 m. Hydraulic power = 1000 × 9.81 × 0.02 × 10 = 1962 W (about 1.96 kW). If the pump is 75% efficient, the motor must supply Input power = 1962 ÷ 0.75 = 2616 W.
FAQ
Why does the input power come out bigger than the hydraulic power?
No pump is perfect. Friction and turbulence waste energy, so at 75% efficiency only 75% of the electrical input becomes useful lifting power — the motor must draw 1962 ÷ 0.75 = 2616 W in the example above.
What happens if I double the height?
The power doubles too, because P is directly proportional to h. Doubling the flow rate Q has exactly the same effect.
How do I convert litres per second to m³/s?
Divide by 1000. For example, 20 L/s = 0.02 m³/s and 1 L/s = 0.001 m³/s.