final I = V/R t = τ 63.2% of final I t

Formula

τ = L ÷ R  •  τ = time constant (s), L = inductance (H), R = total resistance in the circuit (Ω). While the current grows: I(t) = (V ÷ R) × (1 − e−t/τ). After one time constant the current reaches 63.2% of its final value V/R; after 5τ it is within 1% of final and treated as fully settled.

How to use

Worked example

A coil of L = 0.2 H is connected through R = 10 Ω to a 20 V supply.
τ = L ÷ R = 0.2 ÷ 10 = 0.02 s = 20 ms.
Final current = V ÷ R = 20 ÷ 10 = 2 A.
At t = 0.02 s (exactly one τ): fraction = 1 − e−1 = 63.21%, so I = 2 × 0.6321 = 1.264 A.
The current is effectively settled after 5τ = 0.1 s.

FAQ

Why doesn't the current jump straight to V/R?
As the current starts to grow, the inductor's changing magnetic field induces a back-EMF that opposes the growth. The current can only creep up exponentially — fast at first, then slower and slower as the back-EMF fades.

How is this different from an RC circuit?
The maths is the same shape, but the roles swap: an RC circuit has τ = RC and its voltage charges up exponentially, while here τ = L/R and the current grows. In both cases 5τ is the practical "fully settled" time.

What if I switch the circuit off?
The current decays with the same time constant: I(t) = I₀ e−t/τ. The inductor tries to keep the current flowing, which is why opening a switch on a large inductor can produce a spark — the stored energy has to go somewhere.