Thermal Resistance Calculator – R = d/kA for Layers in Series

Use this free Thermal Resistance Calculator to find the thermal resistance R = d/(kA) of a single layer, or of up to 3 layers in series. Enter the area and each layer's thickness and conductivity — the tool shows every layer's R and the combined total.

HOT R₁ R₂ R₃ COLD R total = R₁ + R₂ + R₃

Formula

The thermal resistance of one flat layer is R = d/(kA), in K/W — where d is the thickness (m), k is the thermal conductivity (W/m·K) and A is the area (m²). The resistance per unit area (often called the layer's R-value) is r = d/k in m²·K/W. Layers stacked in series add: Rtotal = R₁ + R₂ + R₃. A bigger R means a better insulator: the heat flow through the stack is Q = ΔT/Rtotal.

How to use

Worked example

A panel of area 5 m² has two layers: insulation (d = 0.1 m, k = 0.04) and brick (d = 0.2 m, k = 0.8).
R₁ = 0.1/(0.04 × 5) = 0.5 K/W (r₁ = 0.1/0.04 = 2.5 m²·K/W)
R₂ = 0.2/(0.8 × 5) = 0.05 K/W (r₂ = 0.2/0.8 = 0.25 m²·K/W)
Rtotal = 0.5 + 0.05 = 0.55 K/W, with total r = 2.75 m²·K/W.
The 10 cm of insulation resists heat flow 10× more strongly than the 20 cm of brick.

FAQ

What is the difference between R and the r-value (d/k)?
R = d/(kA) describes one actual piece of material of a given size, in K/W. The r-value r = d/k leaves the area out (m²·K/W), so it rates the layer itself and lets you compare materials directly — double the thickness, double the r-value.

Why do series resistances add?
The same heat current must pass through every layer in turn, and each layer "uses up" part of the temperature difference. Like electrical resistors in series, the total opposition is the sum of the parts.

How is this related to the U-value?
The U-value is the per-area version turned upside down: U = 1/rtotal. For the worked example, U = 1/2.75 ≈ 0.36 W/m²·K — a respectably insulated panel.