Venturi Meter Calculator – Flow Rate from Pressure Difference
Use this free Venturi Meter Calculator to find the flow rate in a pipe from a pressure reading. Enter the wide and narrow cross-section areas, the pressure difference between them and the fluid density — the calculator combines the continuity equation with Bernoulli's principle to give the flow rate.
Formula
Throat speed: v2 = √( 2ΔP ÷ ( ρ (1 − (A2/A1)²) ) )
Flow rate: Q = A2 × v2, and the wide-section speed is v1 = Q ÷ A1.
The continuity equation (A1v1 = A2v2) says the fluid must speed up in the narrow throat; Bernoulli's equation then says its pressure must fall. Measuring that pressure drop reveals the flow rate — with no moving parts in the pipe.
How to use
- Enter the cross-section areas in m² (for a round pipe, A = πd²/4 — a 0.1 m diameter pipe has A ≈ 0.00785 m²).
- Enter the pressure difference between the wide section and the throat in pascals.
- Enter the fluid density (water = 1000 kg/m³) and click "Calculate Flow Rate".
Worked example
Water (ρ = 1000 kg/m³) flows through a venturi with A1 = 0.01 m² and throat A2 = 0.005 m². The pressure drop is ΔP = 5000 Pa. (A2/A1)² = 0.25, so v2 = √( (2 × 5000) ÷ (1000 × 0.75) ) = √13.33 = 3.65 m/s. Then Q = 0.005 × 3.65 = 0.0183 m³/s = 18.26 L/s, and v1 = 0.0183 ÷ 0.01 = 1.83 m/s.
FAQ
Where are venturi meters used?
In water supply, chemical plants, carburettors and aircraft airspeed systems — anywhere you need to measure flow without blocking the pipe or adding moving parts.
Must A2 be smaller than A1?
Yes. The throat must be narrower than the inlet, otherwise there is no speed increase and no pressure drop to measure. The calculator warns you if A2 ≥ A1.
How accurate is this formula?
It is the ideal (frictionless) result. Real venturi meters are very efficient, so a discharge coefficient of about 0.95–0.98 is applied in practice — multiply Q by that factor for a real-world reading.